Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Feline Med Surg ; 26(2): 1098612X231214930, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38358307

RESUMEN

OBJECTIVES: The objectives of this study were to report the complications in radial and ulnar diaphyseal fractures in cats and to compare the differences in outcome between single and dual bone internal fixation. METHODS: Medical records between 2004 and 2022 were searched retrospectively for cats with antebrachial diaphyseal fractures treated with internal bone-plate fixation. In total, 49 cases were included from six referral hospitals, including one teaching hospital. Patient information was collated, including fracture configuration, location, repair method and clinical outcome as assessed by veterinary physical examination, radiography and owner questionnaire. RESULTS: A total of 47 cats (mean age 4.2 years) were included. Fractures were located distally (24/49, 49%), proximally (13/49, 26.5%) and mid-diaphyseally (12/49, 24.5%). Dual bone fixation was used in 13/49 (26.5%) cases, with only 1/13 (7.7%) having major complications. By comparison, 4/36 (11.1%) of single plated fractures had major complications. Single bone fixation was 14.25 times more likely (95% confidence interval [CI] 2.07-97.99) to have a successful outcome (veterinarian-assigned score of 0) compared with dual bone fixation (P = 0.007). When evaluating owner-assessed outcomes, single bone fixation was 9.4 times more likely (95% CI 1.4-61.96) to have a successful outcome (owner score of 0) compared with dual bone fixation (P = 0.019). CONCLUSIONS AND RELEVANCE: Fractures that were repaired with single bone fixation had a greater chance of a better outcome. Although the difference was not significant, there was a higher major complication rate and a lower minor complication rate for cases treated with single bone fixation compared with dual bone fixation. The majority of fractures were located in the distal diaphysis. Comminution of the fracture and concurrent orthopaedic issues did not significantly affect the outcome. Further prospective studies with standardised follow-up, radiographic assessment, surgeon and implants are required to truly assess the difference between dual and single bone fixation.


Asunto(s)
Enfermedades de los Gatos , Fracturas Óseas , Gatos , Animales , Estudios Retrospectivos , Diáfisis/cirugía , Estudios Prospectivos , Fracturas Óseas/cirugía , Fracturas Óseas/veterinaria , Fijación Interna de Fracturas/veterinaria
2.
Am J Vet Res ; 84(12)2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38041947

RESUMEN

OBJECTIVE: To determine the effects of using either a linear or curvilinear oscillating, battery-powered saw blade on the extent of bone resection, bone fissure or fragmentation, soft tissue trauma, and surgical time for femoral head and neck excision (FHNE) in feline cadavers. ANIMALS: 18 feline cadavers. METHODS: Paired feline cadaveric femora were randomly assigned to either a 10 mm linear or 12 mm curvilinear blade for FHNE by 2 surgical residents. CT of each femur pre- and postoperatively were used to create 3D reconstructions of each femur. The residual remaining or excessively resected bone volume at the ostectomy site was compared to an "ideal" ostectomy line made by a board-certified surgeon on preoperative CTs. RESULTS: There were no significant differences in residual or excessive bone resection by a saw blade (P = .84), between surgeons (P = .65), or in surgery time (P = .39). When compared to the "ideal" ostectomy, the linear saw blade removed slightly less bone compared to the curvilinear blade, but was not statistically significant (P = .82). No fissures or fractures were noted; however, the curvilinear blade removed the entire lesser trochanter in 1 cadaver and the linear blade partially removed the greater trochanter in 1 femur and 2 lesser trochanters in 2 femora. CLINICAL RELEVANCE: The use of a curvilinear blade may be a viable option for performing FHNE in cats. In vivo studies are warranted to determine its efficacy in clinical cases where FHNE is performed and the incidence of complications postoperatively.


Asunto(s)
Enfermedades de los Gatos , Procedimientos de Cirugía Plástica , Animales , Gatos/cirugía , Cadáver , Enfermedades de los Gatos/cirugía , Fémur/cirugía , Cabeza Femoral/cirugía , Procedimientos de Cirugía Plástica/veterinaria , Instrumentos Quirúrgicos/veterinaria , Distribución Aleatoria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...